Off-grid solar system calculator

Enter your daily energy use, your worst-month sun hours and your biggest loads. The calculator sizes the battery bank, the array, the charge controller and the inverter together, so the parts match.

Enter your measurements

From the solar load calculator, inverter losses included.
Days the batteries cover with no sun.
Use your worst month for the season you need power in. See peak sun hours by city.
Sets how much of the rated capacity you plan to use: 80% for LiFePO4 (Victron rates cycle life at 80% depth of discharge), 50% for lead-acid (Trojan recommends 20–50% for long life).
Add up what could run together (microwave + fridge + lights…).
The largest motor or compressor’s starting watts, e.g. 800–1,200 W for a fridge (Champion chart).
Its running watts (already counted in the peak above), e.g. 150–400 W for a fridge. The surge needed is the peak plus that motor’s extra starting watts.
More options: DoD · Headroom · Losses …
%
Blank uses 80% for LiFePO4 and 50% for lead-acid. Check your battery’s data sheet.
%
Your choice of margin so cold, bright days and long loads don’t run equipment at its limit.
%
Wiring, dirt, heat, mismatch and controller losses. 14% is the PVWatts default.
°F
Batteries hold less when cold: Victron gives about 80% for LiFePO4 at 32 °F (0 °C) and 50% at −4 °F (−20 °C); lead-acid about 86% at 32 °F. LiFePO4 must not be charged below 41 °F (5 °C) unless it is self-heating.
Your system3 × 400 W panels · 220 Ah at 25.6 V · 70 A MPPT · 2,000 W inverter (2,500 W surge)
Battery bank
220 Ah · 24 V
12 V 100 Ah batteries
6 batteries · LiFePO4
Solar array (minimum)
1,083 W
Panels
3 panels · 400 W
MPPT controller output current
70 A
Inverter continuous rating
2,000 W
Inverter surge rating
2,500 W
Battery current at peak AC load
65 A
How we got this

Battery: 3,000 Wh × 1.5 days ÷ 80% usable ÷ 25.6 V = 220 Ah (6 batteries)

Panels: 3,000 Wh ÷ (3.5 sun h × 86% × 92% battery round trip) = 1,083 W → 3 panels

Controller: 1,200 W ÷ 24 V × 1.25 = 63 A → 70 A

Inverter: 1,500 W × 1.25 = 1,875 W → 2,000 W; surge: 1,500 W + (1,200 − 200) W = 2,500 W

Before you wire itWire and fuse sizes come from NEC/ABYC ampacity tables and the equipment manual — have a qualified installer check them.

For this job · affiliate link
Battery monitor with shuntA shunt monitor on the bank is how you’ll know whether the system matches this plan in practice — especially in the first winter.
View on Amazon (opens in a new tab)

Next: check the panel wiring voltage.

Quick answers for common sizes

Worked examples for the Off-Grid Solar System Calculator
ExampleAnswer
An off-grid solar system for a house26 × 400 W panels, about 71 kWh of battery, 8,000 W inverter
How much solar for an RV600 W of solar, 200 Ah LiFePO4, 2,000 W inverter (for 2 kWh a day)

The same system at other sun hours

The same system at other sun hours
Peak sun hours per daySolar array (minimum)PanelsMPPT controller output current
21,896 W5 panels104 A
31,264 W4 panels100 A
4948 W3 panels70 A
5758 W2 panels50 A
6632 W2 panels50 A

Worked examples: an off-grid solar system for a house and how much solar for an RV. Want one part at a time? Use the battery bank, solar panel, charge controller and inverter calculators.

How the parts are sized

battery Ah = Wh per day × days of autonomy ÷ usable depth of discharge ÷ battery volts
array W = Wh per day ÷ (peak sun hours × (1 − losses) × battery round-trip efficiency)
MPPT output amps = array W ÷ system volts × (1 + headroom)
inverter W ≥ peak AC watts × (1 + headroom), and surge ≥ the biggest start
  • Battery. Sized for your days of autonomy at a usable 80% for LiFePO4 (Victron rates cycle life at 80% DoD) or 50% for lead-acid (Trojan recommends 20–50% for long life).
  • Panels. Sized to refill a day’s use on your sun hours after PVWatts’ default 14% losses and the battery round trip (92% LiFePO4, per Victron; 80% assumed for lead-acid).
  • Charge controller. For a worked example see what size charge controller for 1000 watts of solar. An MPPT controller’s output current is roughly array watts ÷ battery volts (Victron’s example: 100 W ÷ 13 V = 7.7 A), plus headroom. Its maximum PV input voltage must also exceed your array’s cold open-circuit voltage — check that on the series and parallel calculator.
  • Inverter. Continuous rating above everything that can run together, and a surge rating above the biggest motor start.

Choosing 12, 24 or 48 V

Rules of thumb, not limits. Current = watts ÷ volts, so voltage is the lever that keeps cables and battery currents sensible.
System sizeUsual voltageWhy
Up to ~1,500 W inverter, small van or boat12 VRuns 12 V appliances directly; currents still manageable
~1,500–4,000 W inverter, RV or cabin24 VHalf the current of 12 V for the same power
Above ~4,000 W, homes and large cabins48 VA quarter of the 12 V current; many home inverters are 48 V

What this calculator leaves to you

It sizes the main parts. It does not size wire, fuses, breakers or disconnects — those come from NEC/ABYC ampacity tables and each product’s manual, and a qualified installer should check them. Connecting an off-grid system to a building’s wiring also needs to follow the electrical code; a home system tied to the grid needs a permit and utility approval.

CalculatorSolar Load Calculator →Haven’t got a daily watt-hour figure yet? Start with your appliance list.

What you’ll need

  • 12 V 100 Ah LiFePO4 batteryPremium price

    About 1.28 kWh rated in a box roughly the size of a group 24–31 lead-acid battery at around half the weight. Check the BMS discharge limit and whether it can charge below freezing.

    See options on Amazon (opens in a new tab)
  • 400 W residential-size solar panelPremium price

    Fewer, larger panels for a cabin, shed or ground mount. Their higher voltage usually means an MPPT controller.

    See options on Amazon (opens in a new tab)
  • MPPT solar charge controllerMid-range price

    Converts a higher panel voltage into charging current, so you can wire panels in series and lose less in the cables. Size it on output amps and maximum PV voltage.

    See options on Amazon (opens in a new tab)
  • Pure sine wave inverter, 2000–3000 WPremium price

    For microwaves, coffee makers and power tools. At 12 V these draw hundreds of amps, so the battery and cabling matter as much as the inverter.

    See options on Amazon (opens in a new tab)
  • Battery monitor with shuntMid-range price

    Counts amp-hours in and out, so you see true state of charge instead of guessing from voltage — which barely moves on a LiFePO4 battery until it is nearly empty.

    See options on Amazon (opens in a new tab)

As an Amazon Associate we earn from qualifying purchases. Links to products are affiliate links — they cost you nothing extra and help keep these calculators free.

Frequently asked questions

How big an off-grid solar system do I need?

Start from your watt-hours per day. Each day of autonomy needs that much usable battery; the array needs to refill it on your worst-month sun hours. A 3 kWh-a-day cabin at 3.5 sun hours is roughly 1,100 W of panels and 220 Ah at 24 V of LiFePO4 for 1.5 days.

How much solar do I need for my RV?

It depends on what you run. An RV using 2 kWh a day with a 12 V fridge, lights, fans and a little microwave use needs about 560 W of panels at 4.5 sun hours. See how much solar for an RV.

Can I run a whole house off-grid on solar?

Yes, but it is a big system: the average US home’s 28.4 kWh a day (EIA, 2024) needs roughly 10.3 kW of panels at 3.5 sun hours and about 71 kWh of LiFePO4 for two days. See an off-grid solar system for a house.

Why does the calculator ask for my worst month?

Because an off-grid system has to work on the darkest days you use it. Sizing on the yearly average leaves you short every winter; PVWatts shows Chicago’s lowest month at about 2.7 peak sun hours against 4.5 for the year.

Sources