How to size an off-grid solar system, step by step

Every off-grid system — van, boat, RV, cabin — is sized the same way, in the same order: what you use, how much you store, how fast you refill it, and what converts the power in between. Here are the five steps, the formula for each, and a worked example for a van using 2 kWh a day.

Step 1: the load list (watt-hours per day)

List every appliance with its running watts and the hours it runs each day. Multiply and add. AC appliances on an inverter lose about 10% more — Victron puts modern inverters above 90% efficient — so divide their total by 0.9.

Wh per day = Σ (watts × hours) for DC loads + Σ (watts × hours) ÷ 0.9 for AC loads

Be honest about fridges and anything on a thermostat: use running hours, not hours plugged in. The extension-service rule is a third of the day for a fridge; Victron’s example 12 V fridge runs 25–50% of the time. Starlink’s spec sheets give 75–100 W average for the Standard kit and 25–40 W for the Mini — see how much power the Starlink Mini uses and what size power bank for a Starlink Mini. The solar load calculator adds it all up.

Step 2: the battery bank

bank Ah = Wh per day × days of autonomy ÷ usable depth of discharge ÷ battery voltage

Days of autonomy is how long you want to go with no charging. Usable depth of discharge is about 80% for LiFePO4 (Victron rates cycle life there) and 50% for lead-acid (Trojan recommends 20–50%). For our van: 2,000 Wh × 1.5 days ÷ 0.8 ÷ 12.8 V ≈ 293 Ah — three 100 Ah LiFePO4 batteries. The battery bank calculator does this; what size battery bank for a 2000W inverter shows why a big inverter can need more batteries for current alone.

Step 3: the solar array

array W = Wh per day ÷ (peak sun hours × (1 − system losses) × battery round-trip efficiency)

Peak sun hours come from NREL’s PVWatts for your location and season — for year-round use, the worst month you need. System losses default to PVWatts’ 14%. The battery round trip is about 92% for LiFePO4 (Victron). For the van at 4.5 peak sun hours: 2,000 ÷ (4.5 × 0.86 × 0.92) ≈ 562 W — three 200 W panels, if the roof has room. See peak sun hours by city, the best angle for solar panels in winter and the solar panel calculator.

Step 4: the charge controller

MPPT amps = array W ÷ battery V × (1 + headroom)
max PV voltage > array open-circuit voltage at your coldest temperature

Three 200 W panels into 12 V is 600 ÷ 12 = 50 A, or about 63 A with 25% headroom — a 70 A controller, or move to 24 V and halve it. Then check the voltage: panels in series must stay under the controller’s maximum PV voltage on the coldest morning, when their voltage is highest. What size charge controller for a 400 watt solar panel, what size charge controller for 1000 watts of solar and four solar panels in series vs parallel walk through both checks.

Step 5: the inverter

continuous W ≥ everything that runs together × (1 + headroom)
surge W ≥ that + the largest motor’s start-up extra

If the van’s biggest AC moment is a 1,200 W microwave plus a 200 W fridge, the inverter needs about 1,750 W continuous with headroom — a 2,000 W pure sine inverter — and a surge rating above the fridge’s start. At 12 V that inverter pulls up to about 185 A at full load. See what size inverter to run a microwave.

The worked example in one table

A 12 V van using 2 kWh a day, 1.5 days of autonomy, 4.5 peak sun hours (a sunny-season figure — winter needs more panel). The off-grid solar calculator does all five steps at once.
PartSumResult
Daily useLoad list2,000 Wh
Battery2,000 × 1.5 ÷ 0.8 ÷ 12.8293 Ah → 3 × 100 Ah LiFePO4
Panels2,000 ÷ (4.5 × 0.86 × 0.92)562 W → 3 × 200 W
Controller600 ÷ 12 × 1.2563 A → 70 A MPPT
Inverter(1,200 + 200) × 1.251,750 W → 2,000 W pure sine

Common mistakes

  • Sizing panels on summer sun and wondering why winter runs flat.
  • Counting lead-acid at 100%. Plan on about half.
  • Forgetting current. A big inverter on 12 V can exceed what one battery is designed to deliver.
  • Ignoring cold Voc. Too many panels in series can exceed the controller’s voltage limit on a frosty morning.
  • Skipping fuses and proper cable. This site deliberately doesn’t size them — wire and fuse sizes come from NEC/ABYC ampacity tables and the equipment manual; have a qualified installer check them.

Bigger examples: how much solar for an RV, how many solar panels for a small cabin and an off-grid solar system for a house.

CalculatorOff-Grid Solar System Calculator →Run all five steps with your own numbers.

Frequently asked questions

What order should I size an off-grid system in?

Loads first (watt-hours a day), then the battery, then the panels to refill it, then the charge controller for those panels, then the inverter for your biggest simultaneous AC load.

How many days of autonomy should an off-grid system have?

Commonly one to three. More days means a much bigger battery; many systems pair one or two days of battery with a generator for long cloudy spells.

What voltage should an off-grid system be?

Twelve volts suits small vans and boats; 24 V suits mid-size RVs and cabins; 48 V suits homes. Higher voltage means lower current for the same power.

Sources