How long will a 100Ah battery last with a 200W load?
A 200 W AC load through a 90% inverter runs about 4.6 hours (4 h 36 min) on a 100Ah LiFePO4 battery used to 80%. On a 12 V 100Ah lead-acid used to 50% it is about 2.7 hours on paper and about 2.1 hours once the Peukert correction for its higher current is applied.
How to work it out
- 100 Ah × 12.8 V × 80% usable = 1,024 Wh
- 200 W ÷ 90% inverter = 222.2 W average
- 1,024 Wh ÷ 222.2 W = 4.6 hours (4 h 36 min)
Two hundred watts is a TV and a laptop together, a small blender, or a box fan on high with lights. It is a useful middle figure for evenings in a van or a power cut.
Adjust for your project
More options: DoD · Inverter eff. · Duty …
- In hours and minutes
- 4 h 36 min
- Usable energy
- 1,024 Wh
- Average draw from the battery
- 222.2 W
- Battery current while running
- 17.4 A
Runtime at other loads
| Load | Runtime | Battery current while running |
|---|---|---|
| 25 | 36.9 hours | 2.2 A |
| 50 | 18.4 hours | 4.3 A |
| 100 | 9.2 hours | 8.7 A |
| 200 | 4.6 hours | 17.4 A |
| 500 | 1.8 hours | 43.4 A |
| 1000 | 0.9 hours | 86.8 A |
| 2000 | 0.5 hours | 173.6 A |
What to know about a 200 W load
- On DC it lasts longer. The same 200 W straight from the battery — 12 V appliances, no inverter — runs about 5.1 hours because there is no inverter loss.
- The current is modest. About 17 A at 12.8 V is gentle on any 100 Ah battery and well inside typical BMS limits.
- Lead-acid at 50%. A 100 Ah lead-acid battery has about 600 Wh to give if you want it to last, so 200 W through an inverter is about 2.7 hours on paper — about 2.1 hours after the Peukert correction for an 18.5 A draw.
- Mix it like real life. An evening of 200 W for 3 hours plus a 25 W fridge all day is about 1.27 kWh — more than one 100 Ah battery holds usable. The solar load calculator adds it up.
Heavier loads are on how long a 100Ah battery lasts with a 1000W inverter; lighter, all-night ones on how long a 100Ah battery runs a CPAP.
Different size? Use the full Battery Runtime Calculator.
What you’ll need
- 12 V 100 Ah LiFePO4 batteryPremium price
About 1.28 kWh rated in a box roughly the size of a group 24–31 lead-acid battery at around half the weight. Check the BMS discharge limit and whether it can charge below freezing.
See options on Amazon (opens in a new tab) - Battery monitor with shuntMid-range price
Counts amp-hours in and out, so you see true state of charge instead of guessing from voltage — which barely moves on a LiFePO4 battery until it is nearly empty.
See options on Amazon (opens in a new tab) - Pure sine wave inverter, 1000 WMid-range price
Enough for a CPAP, laptop, TV and small appliances. Pure sine is the safe choice for anything with a motor or sensitive electronics.
See options on Amazon (opens in a new tab)
As an Amazon Associate we earn from qualifying purchases. Links to products are affiliate links — they cost you nothing extra and help keep these calculators free.
Frequently asked questions
How long will a 100Ah battery last with a 200W DC load?
About 5.1 hours (5 h 7 min).
How long will a 100Ah battery last with a 300W load?
About 3.1 hours (3 h 4 min) through a 90% inverter.
How long will a 100Ah battery last with a 100W load?
About 9.2 hours (9 h 13 min) through a 90% inverter.
Other common sizes
- How long a 100Ah battery runs a fridge — 41 hours — a 12 V compressor fridge (50 W, on half the time) on 100Ah LiFePO4
- How long a 100Ah battery lasts with a 1000W inverter — 55 min at full load (12.8 V LiFePO4)
- How long a 200Ah battery lasts with a 2000W inverter — 55 min at full load (12.8 V LiFePO4)
- How long a 100Ah battery runs a CPAP — 15.4 hours at 60 W (LiFePO4, via inverter)
Sources
- Victron Energy — Lithium Battery Smart manual, technical data (opens in a new tab) — LiFePO4 12.8 V: cycle life 2,500 at 80% DoD, 3,000 at 70%, 5,000 at 50% (to 80% of capacity); 92% round-trip efficiency; 12.8 V 100 Ah: recommended continuous discharge ≤100 A (1C), maximum 200 A; capacity about 20% lower at 0 °C; charge only between +5 °C and +50 °C.
- Trojan Battery — Technical support FAQs (opens in a new tab) — “We generally recommend a discharge of 20 to 50% of the battery’s rated capacity even though the battery is capable of being cycled to 80%”; 20-hour and 100-hour ratings; freezing points by state of charge.
- Trojan Battery — 27TMX data sheet (opens in a new tab) — Group 27 flooded: 85 Ah (5-hr), 97 Ah (10-hr), 105 Ah (20-hr), 117 Ah (100-hr); state of charge vs open-circuit voltage table; charger settings.
- Victron Energy — Energy Unlimited (book) (opens in a new tab) — Lead-acid charge efficiency 80–95% (85% suggested as a starting value); battery energy efficiency about 75% for full cycles, about 89% in partial state of charge; inverter efficiencies above 90%.
- Champion Power Equipment — Generator Wattage Chart (opens in a new tab) — Typical running and starting watts for household, RV and job-site appliances (a manufacturer’s planning chart — your nameplate wins).